Bourdon Sensing Pressure Gauge with Diaphragm Seal Unit

Aug 30, 2021
Bourdon Sensing Pressure Gauge with Diaphragm Seal Unit
View Full Size
Pressure Guage :
  • Reference Standard : EN-837
  • Dial Size : 4'' (100mm), Aluminium, white background with Black markings
  • Case & Bezel : SS316, bayonet type bezel, weatherproof to IP-68 as per IS:13947
  • Window : Shatterproof Glass
  • Bourdon : SS316L
  • Socket : SS316L
  • Movement : SS316
  • Connection : ½” NPT(M)
  • Range : 0 to 10 Bar(g)
  • Accuracy : ± 1% FSD
  • Over Range : 130% FSD
  • Zero Reset : External Knob for Zero Setting
  • Blow out Disc : Provided (Neoprene) on Back of case

Diaphragm Seal Unit:
  • Top Chamber : SS316
  • Diaphragm
  • (Wetted Part) : SS316L
  • Connection : 2” 150# RF
  • Filling Fluid : Silicon Oil
  • Accessories : Gauge Saver in SS316
  • Connection: ½” NPTF x ½” NPTM
 

Comtherm PC1 and PC6 Annual PM and Combustion Safety Audit Works at Mineral Processing Plant

Aug 26, 2021
Comtherm PC1 and PC6 Annual PM and Combustion Safety Audit Works at Mineral Processing Plant
View Full Size
Burner operating 24x7 , found burner is operating perfect with no damaged to any burner parts and combustion safety devices.

Comtherm is so reliable and good make . Customer is happy with the performance of this burners .

Maxon Ovenpak EB5 (1600kW) Annual PM and Combustion Safety Inspection for Dryer Aapplication

Aug 26, 2021
Maxon Ovenpak EB5 (1600kW) Annual PM and Combustion Safety Inspection for Dryer Aapplication
View Full Size
We do full inspection and maintenance for customers safety and satisfaction.

Eclipse Ratiomatic RM1000 Annual PM and Combustion Safety Inspection

Aug 26, 2021
Eclipse Ratiomatic RM1000 Annual PM and Combustion Safety Inspection
View Full Size
Eclipse Ratiomatic RM1000 Annual PM and Combustion Safety Inspection for a Nitrogen Hot Bath Vapourizer.

Overhaul works on complete 2x Armstrong Inline Water Pumps and Combustion Blower .

Worm Gearbox up to 250kW, Reduction Ratio Range up to 4900:1

Aug 13, 2021
Worm Gearbox up to 250kW, Reduction Ratio Range up to 4900:1
View Full Size
Size : up to 710mm center distance
Torque: up to 165,000 Nm
Type: Under driven, over driven, vertical units in singale & double reduction
Applications: Conveyor, Ball Mill, Tubemill, Packing, Mixers, Agitators, Cranes, Winches, Folding & Hoisting
Industries: Material handling, food, processing, aerispacem packing & labeling, steel & other process industries

Conducting Flue Gas Analysis - Boston from GECA

Aug 7, 2021
Conducting Flue Gas Analysis - Boston from GECA
View Full Size
In accordance with standards:
  • CEI EN 50379-1
  • CEI EN 50379-2
  • UNI 10389-1 ( Predisposto per combustibili solidi )
  • UNI10845
  • UNI 7129
  • UNI 11137-1

logo CE nero

logo TUV nero



STANDARD FITTINGS OF THIS INSTRUMENT:
  • Replaceable sensor cartridge by the user
  • 150 mm flue gas probe
  • Comburent air temperature
  • Fume filter with condensation
  • Feeder
  • Infrared-ray printer
  • Calibration report

Using Manometer ST200PT for Our Site Work - Innovative Instrument from Our Partner GECA

Aug 7, 2021
Using Manometer ST200PT for Our Site Work - Innovative Instrument from Our Partner GECA
View Full Size

 

COMPLYING WITH STANDARD UNI:

  • UNI EN 1610:2015 - construction and testing of drain connections and sewer pipes
  • UNI EN 806-4:2010 - specifications relating to installations inside buildings for conveying water intended for human consumption
  • UNI EN 14336:2004 - heating systems in buildings
  • UNI EN 1264-4:2009 - radiant systems powered by water for heating and cooling integrated in the structures


​MEASUREMENT SPECIFICATIONS:

 

  • Pressure:Range LOW -50:600mbar (resolution 0,01 mbar)
  • Pressure:Range HIGH 6 bar (resolution - 0,1 mbar)
  • Pressure:misura differenziale +/-1 bar (resolution - 0,1 mbar)
  • Internal temperature +5:+40°C (resolution - 0,1 °C)

Restriction Orifice 1" 1500# Inconel-825

Aug 5, 2021
Restriction Orifice 1" 1500# Inconel-825
View Full Size
  • Construction as per ISA RP3.2

YETEN Combustion MSB50A High Velocity Burner 220kW, Max Working Temperature 1600 Deg C

Jul 21, 2021
YETEN Combustion MSB50A High Velocity Burner 220kW, Max Working Temperature 1600 Deg C
View Full Size
  • Working temperature : Max 1600 Deg C
  • Turn Down: 1:10 with proprotional pressure regulator control. With electronic flow control and Xs air operation, turndown ratio can be increased up to 1:50
  • Suitable for Heavy Duty Conditions
  • Easy Installation, Commissioning & Maintenance
  • Wide Combustion Range
  • Uniform Temperature Distribution
  • Elongated Refractory Life
  • Low NOx and CO Emissions
  • Economical Spare Parts

KOMPASS Solenoid Valve Coil

Jul 21, 2021
KOMPASS Solenoid Valve Coil
View Full Size
  • KOMPASS Coil for Solenoid Operated Directional Control Valve
  • Coil for D4-03-2B2-A256 ·Voltage : AC220/50/50Hz