Siemens Burner Control (LME11.230C2)
Mar 1, 2023Product Description: LME11.230C2 - Burner control, 1-stage, ion, t1=20s, TSA=3s, up to 120kW, AC230V
Stuebbe Butterfly Valve (K210)
Mar 1, 2023Nominal size DN: 50-200
-Material sealing element (in contact with medium): EPDM, FPM
-Connection: Flange
-Actuator: Electric, pneumatic, manual
-Robust chemical valve with clip seal
-Stainless steel spindle for reliable power transmission
-Additional, double shaft seal
-Hand lever with practical locking function
-O rings included in the scope of delivery for wafer type installation
Material: PVC-U, PP, PVDF
Dungs (Valve Proving System) VPS 504 S02, Art. Nr.(219878)
Mar 1, 2023- Equipment operates independent of residual pressure in the range of the permissible operating range.
- Test volume ≤ 4 l
- Setting work not necessary on site
- Short test period: ≈ 10 s, max. 36 s
- Tightness or leaks are displayed by an LED
- External fault display possible for series 02, series 04 and S05
- Group fault alarm optional for S01 (SSM)
- Suitable for TRD systems
- Electrical connection possible by plug connection S01, 02, 03. No rewiring is required for contact allocation as per DIN 4791.
- S04 and S05: electrical connection at screw terminals via PG 13.5 cable entry
- Art. Nr. 219878
Dungs Pressure Regulator (FRS 503)
Mar 1, 2023- Input pressures up to 500 mbar (50 kPa)
- High flow rate
- Sturdy, precise and sensitive regulation of regulator output pressure
- Inlet pressure compensation diaphragms
-Safety diaphragms
- Internal pulse for regulator output pressure as standard, optional external pulse connection optional on both sides
- Rp 3/8 to Rp 2 thread connection
- DN 40 to DN 150 flange connection
Siemens AGG02 Heat-insulating glass, for QRA, with spring washer and O-ring
Mar 1, 2023Product Description: AGG02 - Heat-insulating glass, for QRA, with spring washer and O-ring
Dungs Multibloc® (MB-ZRDLE 405 B01 S20) (227806)
Mar 1, 2023- Dirt trap: Fine-mesh sieve
- One regulator and two main valves: B01
- One one-stage valve and one two-stage valve
- One valve is fast opening, one valve is slow or fast opening
-Solenoid valves up to 360 mbar (36 kPa) as per DIN EN 161 Class A Group 2
- Sensitive setting of output pressure by proportional regulator as per DIN EN 88 Class A Group 2
- High flow rates with low pressure drop
- DC solenoid drive interference degree N
- Main volume restrictor and partial volume restrictor at valve V2
- Hydraulic opening delay
- Flange connections with pipe threads as per ISO 7/1
- Simple mounting, compact, light-weight
- ( MB-ZRDLE 405 B01 S20)
Tecno Control Manometer ST200PT
Mar 1, 2023Additional Functions:
• Pressure gauge function for measuring static and dynamic pressure with measured minimum and maximum indications
• Real-time measurement graphic
• Datalogger function
• Automatic Volume measure
• Automatic autozero
• Possibility of conversion in the different units of measurement
• Measuring of differential pressure
• Measuring of room humidity by probe (optional)
• Internal calendar and clock
• Free programming of all parameters by operator
• Displaying of testing time
• Temperature compensation
• Storing of reports which can be personalized with user’s data
Siemens SQM40.261A21
Mar 1, 2023The actuators are used primarily for load-dependent control of the flow of gas, oil and combustion air:
- In connection with modulating 3-position controllers or continuous controllers (e.g., 4…20 mA) and/or
- directly by burner controls
Article Number: SQM40.261A21| BPZ:SQM40.261A21
Dungs MQM DN 100 (32-650) (292746)
Mar 1, 2023Size (inlet/outlet): DN 100
G-Type: 400
Max. operation pressure: 16 bar
Measurement range min. Vb [m3/h]: 32.0
Measurement range max. Vb [m3/h]: 650
Dungs DMV-DLE 507/11 (222332)
Mar 1, 2023
Technical description The DUNGS double solenoid valve DMV integrates two solenoid valves in one compact fitting.
- Automatic shut-off valves as per DIN EN 161 Class A Group 2
- Two A valves in one housing - Double seat valves
- High flow rates
- Max. operating pressure up to 500 mbar (50 kPa)
- Fast closing
- Fast opening (DMV-D/11) or slow opening (DMV-DLE/11) with adjustable fast stroke for start gas volume
- Adjustable main volume
- DC solenoid
- Mountable closed position signal contact
- Threaded flange
- Compact, light-weightTechnical description The DUNGS double solenoid valve DMV integrates two solenoid valves in one compact fitting.
Dungs VPS 504 S04, Art. Nr.(219881)
Mar 1, 2023- Equipment operates independent of residual pressure in the range of the permissible operating range.
- Test volume ≤ 4 l
- Setting work not necessary on site
- Short test period: min. 10 s, max. 26 s
- Tightness or leaks are displayed by an LED
- External fault display possible for series 02, series 04 and S05
- Group fault alarm optional for S01 (SSM)
- Suitable for TRD systems
- Electrical connection possible by plug connection S01, 02, 03. No rewiring is required for contact allocation as per DIN 4791.
- S04 and S05: electrical connection at screw terminals via PG 13.5 cable entry
- Art. Nr. (219881)
Dungs Solenoid Valve MVD 205/5 AC 230V IP 54 (270486)
Mar 1, 2023Type: MVD 205/5
p Max: 360
DN/Rp:Rp 1/2
Sole-noid No:100
Dungs CPI 400 (266968)
Mar 1, 2023Specifications:
-Max. operating pressure 7 PSI (500 mbar)
-Connection G 1/8” ISO 228
-Temperature range -40 °F to +150 °F (-40 °C to +65 °C)
-Materials Brass housing (standard version) or stainless steel NBR based rubber
METREG Turbine Gas Meter MQM G400 DN100 PN16 Q min : 32 m3/hr, Q max : 650 m3/hr
Feb 27, 2023Key features:
- Meter sizes from G 10 to G 1000
- Flow rates from 1,6 to 1600 m³/h
- Nominal sizes from Rp 1'' 25 to DN 150
- Pressure class PN 4/16
- Measuring ranges up to 1:20
- Maintenance free based on permanent lubrication of the bal bearings
- Meter body made of anodized high-strength aluminium A L2 L1 H1 H1 H2 H2 B C MQM Quantometer Product information
- Meter index head made of plastic as standard, aluminium as an option
- Optional: Manual lubrication of the ball bearings via the oil pump
- Rotating index head (355°)
- Recommended straight inlet pipe ≥ 3DN and outlet pipe ≥ 2DN
- Horizontal and vertical mounting position
- Approval according to DGRL/PED 2014/68/EU (Pressure Equipment Directive)
- Low-frequency pulse output as standard: HF pulse generator as an option