- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
ERB HIGH CAPACITY,WIDE SLOT BURNER
|
ERB HIGH CAPACITY,WIDE SLOT BURNER |
ERB High Capacity, Wide Slot Burners
When you require maximum linear heat, these impingement burners are the answer.
The High Capacity Burner is a direct impingement burner designed specifically for applications requiring maximum heat and absolute balance of the burner flame. They are particularly adaptable to singeing, laminating, drying, curing, heat treating of plastics and similar operations, where positive flame control is essential. They can be constructed in a manner that eliminates all irregularities and breaks in the flame, found in most burners of this type.
Ignition is immediate over the entire flame space with a vast range of turndown and immediate shutoff is assured without flashback. They are fabricated of 1” to 12” sections which are bolted together to the desired burner length, with a continuous ribbon installed to assure uninterrupted flame conditions along the entire length. They can be operated in conjunction with any type of gas and air-gas mixing system. Balanced blue flame ratings per 12” section are set at a maximum of 100,000 BTU for ink drying, cloth singeing, etc. Precision engineered for exacting requirements, Ensign High Capacity Ribbon Burners offer long and trouble free service.
Where absolute flame balance is not essential such as applications for air-heating, catalytic incinerating, fire polishing of glass, etc., these burners may be configured to operate with outputs up to 720,000 BTU per 12” section. They will retain a stable flame where air velocities passing over the burner do not exceed 2500 FPM.
By combining the end feed sections with bottom feed sections, in various configurations, continuous burners up to 42 feet in length have been built. By combining a supply manifold with distributed bottom feed castings, extremely even flame lengths can be obtained with maximum rigidity of the burner.
Available for the High Capacity Burner is a Water Jacket, created for the purpose of keeping the burner perfectly straight during high fire production runs. When tolerances for treating are extremely tight and the flame needs to be as flat to the product as possible, the water jacket allows the excess heat from the burner to be “washed away”. By running chilled water through the water jacket we are able to keep the burner within tolerances not previously achieved with the burner alone.
Download Files
- Datasheet_ENSIGN_High_Capacity_Burners.pdf (8.06 KB)
- High_Capacity_Ribbon_Replacement.pdf (15.44 KB)