- ELECTRICAL PRODUCT
- FIXED GAS AND FLAME DETECTION SOLUTIONS
- GAS PRODUCT
- CONTRIVE BURNER CONTROL DEVICE
- DUNGS GAS COMPONENTS
- ACCESSORIES
- BALL VALVE
- BURNER MANAGEMENT SYSTEMS AUTOMATIC BURNER CONTROLS
- DOUBLE SOLENOID VALVES
- ELECTRO PNEUMATIC VALVES
- FILTER
- GASMULTIBLOC® MULTIFUNCTIONAL GAS CONTROLS
- MOTOR BUTTERFLY VALVES AND ACTUATORS
- PRESSURE REGULATORS
- PRESSURE SWITCHES FOR GAS AND AIR
- SOLENOID VALVES
- SYSTEM ENGINEERING GAS TRAINS - DUNGSHeatEngine
- VALVE PROVING SYSTEMS LINE LEAKAGE TESTERS-LABORATORY - KITCHEN
- View All
- ECLIPSE BURNER PARTS
- ECONEX GAS TRAIN PRODUCT
- ACCESSORIES FOR GEAR MOTORS
- AIR AND GAS BUTTERFLY VALVE
- DIAL PRESSURE GAUGE
- ELECTRIC ACTUATORS
- ENGINEERED GAS SKID & VALVE TRAIN - GAS PRESSURE REDUCTION STATION
- FLAME SUPERVISION - BURNER CONTROL
- FLAME SUPERVISION - UV DETECTION
- GAS BALL VALVE
- GAS FILTER SERIES (FE)
- GAS PRESSURE REGULATOR
- GAS PRESSURE SWITCH
- GAS SOLENOID & SHUT OFF VALVE
- LINEAR CONTROL VALVE SERIES (MPV)
- MODULATING CONTROL VALVE SERIES (MDV-B1..., B1... E)
- MODULATING CONTROL VALVE SERIES (MDV-D1)
- MOTORIZED BUTTERFLY VALVES ELECTRONIC OR PNEUMATIC ACTUATOR
- NEEDLE VALVE
- PACKAGED VALVE TRAINS - GAS SOLENOID & SHUT OFF VALVE
- SAFETY RELIEF VALVE
- SOLENOID BUTTERFLY VALVE SERIES (BFVS)
- TURBINE METER
- TWO-WAY MANUAL PRESSURE COCK WITH BLEED-OFF
- VALVE PROVING SYSTEM
- View All
- ENOLGAS BONOMI VALVE & ACTUATOR
- GAS BURNER COMTHERM UK
- AIR HEATER (AHP)
- AIR HEATER (HEF)
- AIR HEATER (HEM)
- AIR HEATER (HET)
- COMTHERM EK BURNER
- COMTHERM PROCESS CONE (PC) BURNER
- COMTHERM PROCESS PAK (PP) BURNER
- COMTHERM RECIRCULATION SIDE-PLATE (RSP) BURNER
- COMTHERM SIDE-PLATE (SP) BURNER
- COMTHERM TF IMMERSION BURNER
- COMTHERM TFR IMMERSION BURNER
- DIRECT FIRED AIR HEATER
- FUME INCINERATION BURNER
- PROCESS - HEAT NORMAL CAPACITY (PH)
- PROCESS - HEAT NORMAL CAPACITY (PHC)
- View All
- GAS BURNER SANTIN ITALY
- GAS BURNER SELAS USA
- GECA GAS TRAIN EQUIPMENT
- HONEYWELL
- MAXON BURNER PARTS
- MEDENUS GAS TRAIN PRODUCT
- MTI GAS DETECTOR
- POLIX VALVE
- SIEMENS BURNER PARTS
- YETEN COMBUSTION
- View All
- MECHANICAL PRODUCT
- PROCESS MEASUREMENT AND CONTROL
- THERMOPLASTIC SOLUTIONS
- STUEBBE AERATION & VENT VALVES
- STUEBBE BALL VALVES
- STUEBBE BUTTERFLY VALVES
- STUEBBE CHEMICAL PUMP
- STUEBBE DIAPHRAGM VALVES
- STUEBBE DISPLAY AND CONTROL UNIT
- STUEBBE LEVEL MEASUREMENT
- STUEBBE LIQUID FLOWMETERS
- STUEBBE PRESSURE REDUCING VALVES
- STUEBBE PRESSURE RELIEF VALVES
- STUEBBE PRESSURE SENSOR
- STUEBBE WATER JET PUMP
- View All
METREG ELECTRONIC TURBINE METERS MQME (QUANTOMETER)
|
METREG ELECTRONIC TURBINE METERS MQME (QUANTOMETER) |
The MQMe quantometer is based on the principle of a turbine flow meter with an integrated electronic index head. The MQM is designed for flow and volume measurement for natural gas, nitrogen, air (and other gases on request) in non-custody transfer and process applications. The MQM is available in sizes from DN 25 (1´´) to DN 150 (6´´) with a volume flow rate up to 1600 m3/h depending on meter size. The meter housing is made of high strength aluminum. Itis designed as a sandwich construction (installed between two flanges). A volume correction function (AGA NX-19) can be optionally integrated in the electronic index head. Several communication options are available for data transmission: RS 485, M-Bus, Modbus, HF and LF signal as well as a 4 to 20 mA output. On a standard basis the MQMe meter is battery powered with a calculated battery life time of 5 years under standard conditions.
Characteristics
- several options to transmit the measured an calculated data to a digital control system (DCS) or SCADA
- equipped with alternatively RS 485 or M-Bus interface and one high frequency (HF) as well as one low frequency (LF) pulser
- if an external power supply is connected to the MQME one 4 to 20 mA configurable signal is available
- the rotation of the rotor can be scannes additionally with one external high frequency (HF) sensor
- the HF-sensor signal allows the determination of the actual gas flow in high-resolution and can be transmit to any digital control system (DCS) or SCADA for flow control purposes
- integrated electronic volume corrector
Options
- WFactory calibration measuring range 1:20
- integrated volume corrector (incl. pressure & temperature sensors)
- analog output (4-20 mA, 24 VDC needed)
- RS485 (M-bus not possible)
- M-Bus (RS485 not possible)
- additional HF sensor (external power supply needed)
- Oil pump
- 1x thermowell
- Test certificate 3.1 with detailed materials list
Sizes: | 1' (DN25) to 6' (DN150) |
Connections: | |
Materials: | Meter body anodized aluminium / Meter head made of polymer material or aluminium (optional) |
Flow Rates: | 16 to 1600 m³/h |
Medium: | Gas |
Pressure Class: | PN10/PN16 or ANSI Class 150 |
Temperature: | |
Approvals: | PED and ATEX (zone 1) |
Notes: | (a) Horizontal or vertical mounting position (b) Maintenance free based on permanent lubrication (c) Protection class IP65 |
Download Files
- MT_MQMe_2_Seiten_EN_2016_web_(1).pdf (399.66 KB)